Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCCB
Samples:
US$ 20/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
BYM
Poles Number
3p/4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Rated Operation Voltage
400/415V
Standard
IEC60947-2
Rated Insulation Voltage
800V
Frequency
50/60
Button
on/off
Operating Temperature Range
-10c to 50c
Degree of Protection
IP20
Tripping Curve
B.C.D
Transport Package
Carton
Trademark
OEM ODM
Origin
China
HS Code
853620000
Production Capacity
40000

Product Description


CE Approved MCCB 3p 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit Breaker

Product Description

 

Standard:
 circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

 MCCB(Standard use environment for  MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          2-poles, 3-poles
According to the rated current:                               Fix type

 

Product Parameters

 

Thermal-Magnetic fixed type Circuit Breakers  
Model XHM1-800
Breaking Capacity Code L M H
Rated Current of Frame size- Inm                               (A) 800
Rated Current-In(40,50 or 55ºC)                                                    (A) 630.640.660.680.700.720.740.760.780.800  A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                         (V) 800V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                               (V) 400/415V
Number of Pole   3 4
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO       (KA) 65 100 65
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO  (KA) 42 65 42
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO        (KA) 41/0.3 73.5/0.25 110/0.25
Rated impulse withstand Voltage -Uimp                                     (V) 8000
Dielectric Propery (V)     3000
lonization distance                                                                      (mm) ≤50/0
Endurance   Total Cycles   8000
Electrical Life   1000
Mechanical Life   7000
Over Current trip  Thermal and Magnetic release fix type               
Category   (EN 14048.2/IEC 60947-2) Main circuit   A/0
Auxiliary circuit   AC-15
Under Voltage Release  
Shunt Release        
Auxiliary Contact     
Alarm Contact       
Auxiliary Contact and Alarm Contact  
Handle Operation Mechanism  
Electrical Operastion Mechanism  
Terminal cover       
Phase seperator     
Extention Handle    -
W (mm) 3P 210
4P 280
L (mm) 3P 280
4P 280
H (mm) 3P 115.5
4P 115.5
Weight Fixed version 3P/4P  
Plug-in version 3P/4P  
Draw out version 3P/4P -
 

Detailed Photos


MCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit Breaker
MCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit Breaker
MCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit BreakerMCCB 63A 100A 125A 250A 400A 630A 800A 1250A 1600A AC Molded Case Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
Number of Employees
2
Year of Establishment
2022-04-11