Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Still deciding? Get samples of US$ 20/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Standard:
circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;
MCCB(Standard use environment for MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;
Classification:
According to the poles: 2-poles, 3-poles
According to the rated current: Fix type
Thermal-Magnetic fixed type Circuit Breakers | |||||
Model | BYM1-250 | ||||
Breaking Capacity Code | L | H | |||
Rated Current of Frame size- Inm (A) | 250A | ||||
Rated Current-In(40,50 or 55ºC) (A) | 100 -125 - 140-160(150)A-180-200-225-250 | ||||
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz (V) | 800V | ||||
Rated operation Voltage -Ue(a.c.) 50-60Hz (V) | 400/415V | ||||
Number of Pole | 3 | 3 | 4 | 3 | |
Rated ultimate short Circuit breaking Capacity kA Icu AC400V/50Hz O-CO (KA) | 35 | 50 | 25 | 80 | |
Rated service short Circuit breaking Capacity kA Ics AC400V/50Hz O-CO-CO (KA) | 25 | 35 | 15 | 50 | |
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO (KA) | 41/0.3 | 73.5/0.25 | 110/0.25 | ||
Rated impulse withstand Voltage -Uimp (V) | 8000 | ||||
Dielectric Propery (V) | 3000 | ||||
lonization distance (mm) | ≤50/0 | ||||
Endurance | Total Cycles | ||||
Electrical Life | 7500 | ||||
Mechanical Life | 10000 | ||||
Over Current trip | Thermal and Magnetic release fix type | √ | |||
Category (EN 14048.2/IEC 60947-2) | Main circuit | A/0 | |||
Auxiliary circuit | AC-15 | ||||
Under Voltage Release | √ | ||||
Shunt Release | √ | ||||
Auxiliary Contact | √ | ||||
Alarm Contact | √ | ||||
Auxiliary Contact and Alarm Contact | √ | ||||
Handle Operation Mechanism | √ | ||||
Electrical Operastion Mechanism | √ | ||||
Terminal cover | √ | ||||
Phase seperator | √ | ||||
Extention Handle | - | ||||
W (mm) | 3P | 107 | |||
4P | 142 | ||||
L (mm) | 3P | 165 | |||
4P | |||||
H (mm) | 3P | 86 | |||
4P | 103 | ||||
Weight | Fixed version 3P/4P | ||||
Plug-in version 3P/4P | |||||
Draw out version 3P/4P | - |