Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCCB
Samples:
US$ 30/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
XHM1-125
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Rated Operation Voltage
400/690
Standard
IEC60947-2
Rated Insulation Voltage
250V
Transport Package
Carton
Trademark
OEM ODM
Origin
China
HS Code
853620000
Production Capacity
40000

Product Description


Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCB
Product Description

MCCB Low Voltage

160A 200A 225A 250A 

Moulded Case Circuit Breaker MCCB

Standard:
 circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

 MCCB(Standard use environment for  MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          2-poles, 3-poles
According to the rated current:                               Fix type

 

Product Parameters

 

Thermal-Magnetic fixed type Circuit Breakers  
Model BYM1-800
Breaking Capacity Code   M H
Rated Current of Frame size- Inm                               (A) 800A
Rated Current-In(40,50 or 55ºC)                                                    (A) 630.700.800
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                         (V) 800V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                               (V)   400/690 400 400
Number of Pole     3 4 3
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO       (KA)   50 86 100
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO  (KA)   20 30 65
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO        (KA)   73.5/0.25 110/0.25
Rated impulse withstand Voltage -Uimp                                     (V) 8000
Dielectric Propery (V)     3000
lonization distance                                                                      (mm) ≤100/0
Endurance   Total Cycles   8000
Electrical Life   1000
Mechanical Life   7000
Over Current trip  Thermal and Magnetic release fix type               
Category   (EN 14048.2/IEC 60947-2) Main circuit   A/0
Auxiliary circuit   AC-15
Under Voltage Release  
Shunt Release        
Auxiliary Contact     
Alarm Contact       
Auxiliary Contact and Alarm Contact  
Handle Operation Mechanism  
Electrical Operastion Mechanism  
Terminal cover       
Phase seperator     
Extention Handle    -
W (mm) 3P 210
4P 280
L (mm) 3P 280
4P 280
H (mm) 3P 115.5
4P 115.5
Weight Fixed version 3P/4P 1.2/1.6
Plug-in version 3P/4P 1.4/1.8
Draw out version 3P/4P -
 
Detailed Photos

MCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit Breaker

MCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit Breaker
MCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit BreakerMCCB 2p 3p 4p Breaker Switch Bym1 Series 100A 160A 250A 400A 630A Moulded Case Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
Number of Employees
2
Year of Establishment
2022-04-11