Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCCB
Samples:
US$ 20/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
BYM1
Poles Number
3p/4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Rated Operation Voltage
400/415V
Standard
IEC60947-2
Rated Insulation Voltage
800V
Transport Package
Carton
Trademark
OEM ODM
Origin
China
HS Code
853620000
Production Capacity
40000

Product Description


Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB

Product Description

 

Standard:
 circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

 MCCB(Standard use environment for  MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          2-poles, 3-poles
According to the rated current:                               Fix type

 

Product Parameters

 

Thermal-Magnetic fixed type Circuit Breakers  
Model XHM1-125
Breaking Capacity Code L M H
Rated Current of Frame size- Inm                               (A) 160A
Rated Current-In(40,50 or 55ºC)                                                    (A) 10- 12,5-16-20 - 25 - 32 - 40  - 50 - 63 - 80 - 100 -125 - 160(150)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                         (V) 800V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                               (V) 400/415V
Number of Pole   3 4
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO       (KA) 25 35 50
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO  (KA) 12.5 22 37.5
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO        (KA) 41/0.3 73.5/0.25 110/0.25
Rated impulse withstand Voltage -Uimp                                     (V) 8000
Dielectric Propery (V)     3000
lonization distance                                                                      (mm) ≤50/0
Endurance   Total Cycles   8000
Electrical Life   1000
Mechanical Life   7000
Over Current trip  Thermal and Magnetic release fix type               
Category   (EN 14048.2/IEC 60947-2) Main circuit   A/0
Auxiliary circuit   AC-15
Under Voltage Release  
Shunt Release        
Auxiliary Contact     
Alarm Contact       
Auxiliary Contact and Alarm Contact  
Handle Operation Mechanism  
Electrical Operastion Mechanism  
Terminal cover       
Phase seperator     
Extention Handle    -
W (mm) 3P 92
4P 122
L (mm) 3P 150
4P 150
H (mm) 3P 68
4P 86
Weight Fixed version 3P/4P 1.2/1.6
Plug-in version 3P/4P 1.4/1.8
Draw out version 3P/4P -
 

Detailed Photos


Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB
Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB
Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCBNinewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
Number of Employees
2
Year of Establishment
2022-04-11