消息
×
loading..
x

M1 MCCB Moulded Case Circuit Breaker for Power Distribution

US$12.00 - 250.00 10 Pieces (MOQ)
Port:
Xiamen, China
Production Capacity:
40000
Payment Terms:
L/C, T/T, Western Union

Last Login Date:

Sep 19, 2025

Main Products:

Acb RCCB MCCB MCB Capacitor etc, Capacitor, RCD RCBO Acb, Miniature Circuit Breaker, Surge Protector Device, Intelligent Universal Circuit Breaker, Moulded Case Circuit Breaker, Control and Protection Switch, Load Isolation Switch

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
BYM1LE
Breaking Capacity
Low Voltage Circuit Breakers
Operation
Electric Type
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
MCCB
Poles Number
3p/4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Rated Operation Voltage
400/415V
Standard
IEC60947-2
Rated Insulation Voltage
800V
Trademark
OEM ODM
Transport Package
Carton
Origin
China
HS Code
853620000

Product Description

Product Description
 M1 MCCB Moulded Case Circuit Breaker for Power Distribution

Standard:
 circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

 MCCB(Standard use environment for  MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          2-poles, 3-poles
According to the rated current:                               Fix type

 

Product Parameters

 

Thermal-Magnetic fixed type Circuit Breakers 
ModelXHM1-125
Breaking Capacity CodeLMH
Rated Current of Frame size- Inm                               (A)160A
Rated Current-In(40,50 or 55ºC)                                                    (A)10- 12,5-16-20 - 25 - 32 - 40  - 50 - 63 - 80 - 100 -125 - 160(150)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                         (V)800V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                               (V)400/415V
Number of Pole  34
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO       (KA)253550
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO  (KA)12.52237.5
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO        (KA)41/0.373.5/0.25110/0.25
Rated impulse withstand Voltage -Uimp                                     (V)8000
Dielectric Propery (V)    3000
lonization distance                                                                      (mm)≤50/0
Endurance  Total Cycles  8000
Electrical Life  1000
Mechanical Life  7000
Over Current trip Thermal and Magnetic release fix type              
Category   (EN 14048.2/IEC 60947-2)Main circuit  A/0
Auxiliary circuit  AC-15
Under Voltage Release  
Shunt Release        
Auxiliary Contact     
Alarm Contact       
Auxiliary Contact and Alarm Contact  
Handle Operation Mechanism  
Electrical Operastion Mechanism  
Terminal cover       
Phase seperator     
Extention Handle   -
W (mm)3P92
4P122
L (mm)3P150
4P150
H (mm)3P68
4P86
WeightFixed version 3P/4P1.2/1.6
Plug-in version 3P/4P1.4/1.8
Draw out version 3P/4P-
 
Detailed Photos

Send your message to this supplier
Ms. sabriya

Post a Sourcing Request Now

People who liked this also liked