Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: ELCB
Samples:
US$ 30/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Factory photo
Overview

Basic Info.

Poles Number
2
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
VDE, ISO9001-2000, CE, CB, CCC
Ambient Temperature
-5 to +40 Degree Centigrade
Type of Trip
Thermal/Magnetic Release
Type of Terminal
Lug Type and Pin Type
Prodcut Standard
Confirming to IEC/En60898
Transport Package
Carton
Specification
3P
Trademark
OEM, ODM
Origin
China
HS Code
8536200000
Production Capacity
300000PCS/Year

Product Description


High Quality Residual Current Operated Circuit Breaker  RCCB with Silver Contact 10ka Ce CB TUV
 
Product Description


BYB1LE-63 series Residual current circuit breaker(without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation. It is applicable to industrial site, commercial site, tall building and civil house.

It complies with standard of IEC/EN61008.1 and GB16916.1.

Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.

 
Product Parameters
 
lectrical features  
Type(an aware form of the earth leakage sensed) B
Rated current In 25,40,63A
Poles 2P 4P
Number of poles versus modules 2P= 4mod;4P=4 mod
Rated voltage Ue 2P:230V~ 4P:400V~
Insulation voltage UI 500V
Rated frequency 50/60Hz
Rated sensitivity IAn 0.03A 0.1A 0.3A
Rated residual making and breaking capacity Im 500(In=25-40A)630(In=63A)
Short-circuit current lnc=lAc 10000A
SCPD fuse 10000
Break time under IAn ≤0.1S
Rated impulse withstand voltage(1.2/50)Uimp 6000V
Dielectric test voltage at and ind.Freq.for 1min 2.5kV
Electrical life and Mechanical life 4000
Pollution degree 2
Installation  
Fault current indicator NO
Protection degree IP20
Ambient temperature(with a daily average of 35 ) -5~+40°ºC
Storage temperature -25+70ºC
Terminal connection type Cable/U-type busbar/Pin -type busbar
Terminal size top/bottom for cable 35mm²
18-3
Tightening torque 3.5N*m
22
Mounting On DIN rail FN 60715 (35mm)by means of the fast clip device
Connection From top


25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB
Detailed Photos



25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB

25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB
Factory photo
25A 40A 63A Protection Device RCCB 2p RCD Residual Current Circuit Interrupter RCCB

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
Number of Employees
2
Year of Establishment
2022-04-11